UV Air Purifier Coil Cleaner - HVAC UV Sterilizer Unit

Model No.︰

YUP165 20%OZONE

Brand Name︰

YUP

Country of Origin︰

China

Unit Price︰

US $ 20 / pc

Minimum Order︰

20 pc

Share on:

Product Description

 The EPA says indoor air quality maybe 5 times more polluted than outdoor air and even greater in high traffic areas. This unit is an ideal choice to destroy airborne virus and bacteria moving through your home or business's air conditioner system, and the destroying of spore growth (mold) growing on coils and in drain pans which greatly improves the operating efficiency of the A/C and reduces yearly operating cost.
This hospital grade UV-C (254 nm) system helps the immune compromised person and healthy person. Research studies show a 60% reduction of illness from airborne virus, bacteria, molds and neutralizes Volatile Organic Compounds (VOC's) caused by air cooling or heating systems. Ventilation systems are a superhighway for airborne pathogens to mix and contaminate the air throughout any building. Our germicidal UV system helps stop the growth of infectious airborne microbes before they cause sickness, disease and infection. Produce's no ozone.

Who can benefit from these features:
Young
Elderly
Neutropenic effects of Chemotherapy/Radiation
HIV/AIDS
COPD
Chronic Bronchitis
Asthma
Allergies
Tuberculosis
Some Sleeping Disorders
Animal Husbandry
Bakeries
Business Offices
Burn Centers
Cancer Center
Clean Rooms
Dairy Plants
Doctor and Dental Office Food Manufacturing
HIV / AIDS Clinics
Homeless Shelters
Hospitals
ICU
Kennels
Laboratories
Meat Processing Plants Nursing Homes
Pharmaceutical Labs
Operating Rooms
Schools
TB Clinics
Retirement Homes
Veterinary Clinics
Each unit is constructed for easy installation into the side of a standard air duct with minimum air velocity drop
External mounting for air handler or duct
Inspection port and safety interlock switch
 
BE SURE TO READ WARNINGS AND CAUTIONS BEFORE INSTALLING OR USING 
YOUR UV SYSTEM
WARNING
UV Light Hazard. 
Harmful to bare skin and eyes.
Can cause temporary or permanent loss of vision.
Never look at bulbs while illuminated.
View illumination only through light indicator located 
on lamp handle. 
To prevent exposure to ultraviolet light, disconnect 
power to Ultraviolet System before servicing any part 
of heating and air conditioning system.
Do not mount device in location that allows ultraviolet 
light to be seen after installation.
Do not attempt to bypass duct mount switch.
Do not attempt to open housing; unit is sealed to 
prevent ultraviolet light exposure.
CAUTION
Personal Injury Hazard.
Power supply can cause electrical shock.
Disconnect power supply before cleaning or replacing 
ultraviolet bulb(s).
Do not open base unit or lamp handle; there are no 
user-serviceable components inside.
CAUTION
Breakable Glass Hazard.
Can cause personal injury.
Be careful when inserting bulb(s) into lamp base.
Wear protective gloves when handling bulb(s).
CAUTION
UV Lamp Burn Hazard.
Harmful to bare skin.
Can cause severe burns.
Disconnect power 15 minutes before removing the 
ultraviolet bulb(s).
MERCURY NOTICE
This device contains mercury in the sealed ultraviolet 
bulb(s). Do not place your used bulb(s) in the trash. 
Dispose of properly. 
Broken Bulb Cleanup.
Do not use a household vacuum. 
Sweep debris (phosphor/glass) into a plastic bag and 
dispose of properly.
Contact your local waste management authority for 
instructions regarding recycling and the proper 
disposal of old bulb(s).
CAUTION
Equipment Damage Hazard. 
Ultraviolet light can cause color shift or structural 
degradation of plastic HVAC materials.
Select mounting location that prevents exposure to 
plastic components with unknown resistance to 
ultraviolet light. Three-feet minimum is recommended 
between ultraviolet lamp and plastic-fabricated 
devices (such as wires and non-fiberglass media 
filters).
NOTE: Most drain pans and humidifiers are UV-C resistant. 
Consult Honeywell’s UV exposure white paper, Form 
No. 50-8788.
CAUTION
Sharp Edges Hazard.
Can cause personal injury.
Be careful when inserting ultraviolet device into the 
sheet metal cutout.
Wear protective gloves when working
 
When Installing this Product…
1. Read these instructions carefully. Failure to follow them 
could damage the product or cause a hazardous 
condition.
2. After installation is complete, check out product operation as provided in these instructions.
Selecting Mounting Location
Depending on installation location, the UV System can 
operate as an Air Treatment System or as a Surface 
Treatment System.
1. The UV System can be mounted in any orientation.
2. Choose a location that is readily accessible for regular 
inspection and cleaning.
3. The UV Air Treatment System requires an easily-accessible, flat mounting surface on the metal return air duct 
of the HVAC system. The UV Surface Treatment System requires an easily-accessible, flat mounting surface 
on the metal supply air duct of the HVAC system. The 
UV Surface Treatment System must be located so the 
lamp surrounds the evaporator coil and drip pan with 
ultraviolet light.
4. The duct mounting location must be a minimum of 8 in. 
wide. See Fig. 3.
5. The depth of the duct must accommodate the full length 
of the ultraviolet bulb as shown in Fig. 3.
6. The unit should be located as far away as possible from 
any rubber or plastic components, such as isolators, in 
the duct.
IMPORTANT
If mounting options are limited, protect plastic or rubber materials listed in CAUTION with ultravioletresistant material such as aluminum foil duct tape.
7. The space adjacent to the mounting location must be 
large enough to allow for ultraviolet bulb installation and 
removal.
8. A 120V electrical outlet must be within range of the unit 
to plug in the power cord.


Product Image

www.lampuv.com